General
|
|
|
Frequency Band |
902-928 MHz |
|
Frequency Hopping Sequence |
4
selectable groups, each
containing 63 frequencies |
|
Operation |
Half duplex |
|
Radio Addresses |
64,260 |
|
Radio Modes |
Master, Slave, Repeater/Slave |
|
Security Codes |
65,536 |
Data Characteristics
|
|
|
Serial Port |
RS-232 |
|
Serial Connector |
DB9 |
|
Antenna Connector |
MCX female |
|
Data Port Rates |
1200, 2400, 4800, 9600, 19200,
38400 baud (Asynchronous) |
|
Data Rate in RF Channel |
9600 bps |
|
Flow Control |
Selectable between Hardware or
None |
|
Typical Latency |
70 ms |
|
Auto-Routing |
MODBUS RTU, AB DF1 protocols |
|
Error Correction/Detection |
ARQ with CRC-16 |
|
RF Channel Protocol |
Iris |
Transmitter
|
|
|
Power Output |
1
Watt (30dBm) |
|
Duty Cycle |
50% |
|
Output Impedance |
50 ohms |
|
Transmitter Keying |
Data activated |
|
Maximum SWR (with no damage) |
Infinite at all phase angles |
Receiver
|
|
|
Type |
Double conversion
superheterodyne |
|
Data Threshold |
Less than Aa^?a^?oe110dBm |
|
Acquisition Threshold |
Less than Aa^?a^?oe113dBm |
Primary Power
|
|
|
Voltage |
9
to 28 VDC |
|
Supply Current Aa^?a^?oe Transmitting |
170mA at 24 VDC |
|
Supply Current Aa^?a^?oe Receiving |
16mA at 24 VDC |
|
Fuse |
0.5A polyfuse |
|
Reverse Polarity Protection |
YES |
Environmental
|
|
|
Humidity |
0% - 95% at 40oC,
non-condensing |
|
Temperature |
Operating: -40o to
158oF (-40o
to 70oC)
Storage: -40o to 185oF
(-40o to 85oC) |
|
Size |
4.2Aa^?A^? x 3.0Aa^?A^? x 0.88Aa^?A^? (105mm x
75mm x 22mm) |
|
Weight |
4.9 oz (140 g) |
|
Mounting |
DIN rail |
|
Enclosure |
NEMA 1 (IP 30) |
Diagnostics
|
|
|
Indicators |
External LED's (RF, TX, RX) |
|
Digital Outputs |
RSSI, Link status |
Agency Approvals
|
|
|
FCC |
Part 15.247 |
|
Industry Canada |
RSS 210 |
|
CSA/C & US |
Class 1 Div 2; Groups A, B, C, D
(pending) |